Configures the port speed level.
Synopsis
portcfgspeed [slotnumber/]portnumber speed_level
Availability
admin
Description
Use this command to configure the speed of a port to a particular level. After this command is issued, the
port is disabled and enabled so that the port comes up with the new speed setting. The configuration is
saved in the flash memory and is persistent across switch reboot or power cycle.
If the command is specified without an operand, you are prompted to enter the speed value.
Enter Ctrl+D to cancel the configuration update.
The output of the portShow command displays the current achieved speed of a port and the
portCfgShow command displays the user-desired speed setting for a port.
Operands
This command has the following operands:
Examples
To configure the speed of a port to 2 Gb/s:
See also
portCfgShow
portShow
switchCfgSpeed
portCfgSpeed
slotnumber Specify the slot number of the port to be configured, followed by a slash
(/) (for bladed systems only).
portnumber Specify a port number to be configured, relative to its slot for bladed
systems. Use switchShow to display a list of valid ports.
speed_level Specify the speed of a port. This operand is required. Valid values are
one of the following:
0 Autosensing mode. The port automatically configures for the
highest speed.
1 1-Gb/s mode. The port is at fixed speed of 1 Gb/s.
2 2-Gb/s mode. The port is at fixed speed of 2 Gb/s.
4 4-Gb/s mode. The port is at fixed speed of 4 Gb/s.
switch:admin> portcfgspeed 2/3, 2