HP StorageWorks Fabric OS 5.0.0 Command Reference Guide (AA-RW1MA-TE, May 2005)

Fabric OS 5.0.0 command reference guide 481
No_Card
No_Module
No_Light
No_Sync
In_Sync
Laser_Flt
Port_Flt
Diag_Flt
Lock_Ref
No interface card present
No module (SFP or other) present
Module not receiving light
Receiving light but out of sync
Receiving light and in sync
Module is signaling a laser fault
Port marked faulty
Port failed diagnostics
Locking to the reference signal
portScn Last state change notification for port.
portId 24-bit D_ID for port.
portWwn Port WWNs of device(s) connected.
Distance The port's long-distance level. In case of LD mode, the user configured
limit and actual distances also are displayed. (Refer to
portCfgLongDistance)
portSpeed The port's fixed speed level (1 Gb/s or 2 Gb/s) or negotiated speed (N1
Gb/s or N2 Gb/s) level.
Interrupts Total number of interrupts.
Unknown Interrupts that are not counted elsewhere.
Lli Low-level interface (physical state, primitive sequences).
Proc_rqrd Frames delivered for embedded N_Port processing.
Timed_out Frames that have timed out.
Rx_flushed Frames requiring translation.
Tx_unavail Frames returned from an unavailable transmitter.
Free_buffer Free buffer available interrupts.
Overrun Buffer overrun interrupts.
Suspended Transmission suspended interrupts.
Parity_err Real Tx data-parity error.
Table 18 portshow display fields (continued)
Field Description