HP StorageWorks Fabric OS 5.0.0 Command Reference Guide (AA-RW1MA-TE, May 2005)

482 Fabric OS commands
The second column displays link error status block counters.
The third column displays the number of F_RJTs and F_BSYs generated. For L_Ports, the third column also
displays the number of LIPs received, number of LIPs transmitted, and the last LIP received.
Operands
This command has the following operands:
Examples
To display the state of a port:
2_parity_err Secondary Tx data-parity error. These are not real Tx data-parity errors
but rather forced by the ASIC due to certain central memory errors so that
the transmitter will abort the frame. This field will only be displayed when
there are errors.
CMI_bus_err Control message interface errors.
Table 18 portshow display fields (continued)
Field Description
slotnumber Specify the slot number for a Core Switch 2/64 or SAN Director
2/128. For all other switches, this operand is not required. The
slot number must be followed by a slash ( / ) and the port
number, so that each port is represented by both slot number (1
through 4 or 7 through 10) and port number (0 through 15).
The Core Switch 2/64 and SAN Director 2/128 have a total of
10 slots. Slot numbers 5 and 6 are control processor cards; slots
1 through 4 and 7 through 10 are port cards. On each port
card, there are 16 ports, counted from the bottom, numbered 0
to 15.
portnumber Specify a port number. Valid values for port number vary,
depending on the switch type. This operand is required.
switch:user> portshow 2/15
portName: Tape drive 8
portHealth: HEALTHY
Authentication: type DHCHAP, hash SHA1, group 0
portDisableReason: None
portCFlags: 0x0
portFlags: 0x20001 PRESENT DISABLED LED
portType: 1.1
portState: 2 Offline
portPhys: 2 No_Module
portScn: 0
(continued on next page)