HP StorageWorks Fabric OS 5.0.0 Command Reference Guide (AA-RW1MA-TE, May 2005)

504 Fabric OS commands
Displays power supply status.
Synopsis
psshow
Availability
all users
Description
Use this command to display the current status of the switch power supplies.
The format of the display varies according to the switch model and number of power supplies present.
Depending upon switch model, OEM serial ID data displays after each power supply status line.
The status of each supply is displayed as:
Optionally, after each power supply status line is the OEM serial ID data, depending on the switch model.
Operands
none
Examples
To view the status of the power supply for a Core Switch 2/64:
psShow
OK Power supply functioning correctly.
absent Power supply not present.
Unknown Unknown power supply unit installed.
Predicting Failure Power supply is present but predicting failure.
faulty Power supply present but faulty (no power cable, power switch
turned off, fuse blown, or other internal error).
switch:admin> psShow
Power Supply #1 is OK
DELTA DPS-1001AB-1E 23000000601 S1 IXD0111000088
Power Supply #2 is faulty
DELTA DPS-1001AB-1E 23000000601 S1 IXD0111000162
Power Supply #3 is OK
DELTA DPS-1001AB-1E 23000000601 S1 IXD0111000120
Power Supply #4 is absent