Enables or disables ESD mode.
Synopsis
setesdmode [mode | -show]
Availability
admin
Description
Use this command to enable or disable ESD mode. The mode is saved in flash memory and stays in that
mode until the next execution of setEsdMode. The mode becomes active as soon as this command is
executed. It does not require a reboot to take effect.
ESD mode modifies the behavior of the diagnostic test methods and post scripts. The exact behavior
varies but most commonly consists of disabling the ports defined with diagEsdPorts when spinSilk
or other functional tests are run for ESD or EMI testing purposes.
Operands
This command has the following operands:
If no operand is specified, the current value displays.
Examples
To display the ESD mode:
See also
diagEsdPorts
spinSilk
setEsdMode
mode Specify 1 to enable ESD mode, 0 to disable ESD mode. This
operand is optional.
-show Specify this operand to display the current mode setting. This
operand is optional.
switch:admin> setesdmode -show
Esd Mode is 0 (Disabled).