HP StorageWorks Fabric OS 5.0.0 Command Reference Guide (AA-RW1MA-TE, May 2005)

622 Fabric OS commands
Operands
This command has the following operands:
Examples
To test cascading ISL links:
Diagnostics
When it detects failure(s), the test might report one or more of the following error messages:
DATA
ERR_STAT
ERR_STATS
ERR_STATS_2LONG
ERR_STATS_BADEOF
ERR_STATS_BADOS
ERR_STATS_C3DISC
ERR_STATS_CRC
ERR_STATS_ENCIN
ERR_STATS_ENCOUT
ERR_STATS_TRUNC
-nmegs count Specify in millions the number of frames to send. The test will progress
until the specified number of frames has been transmitted on each port.
The default value is 10 million frames.
This command only approximately counts the frames and the actual
number of frames sent will be slightly larger, particularly at 2 Gb/s link
speeds.
-ports itemlist Specify a list of user ports to test. By default, all of the ISL ports in the
current switch will be tested. Refer to itemList help pages for further
details.
-setfail mode Instruct spinFab how to mark failed ports. If set to 1, it will mark
failing ports as FAILED. If set to 0, it will not mark failed ports as
FAILED. It is to minimize the impact on live fabrics. This test normally
logs errors but does not set the port status to FAILED. This parameter is
provided to force the failing ports to be marked as FAILED in the same
manner as other diagnostics. In test or qualification environments
without live traffic, this might be useful with large values of -nmegs
count. This mode is disabled by default.
-domain value Specify a remote domain to which the switch is connected. The default
is to automatically determine the remote domain number. This might not
work properly in certain conditions.
switch:admin> spinfab -ports 1/0 - 1/2
spinfab running...
spinfab: Completed 11 megs, status: passed.
port 0 test status: 0x00000000 -- passed.
port 1 test status: 0x00000000 -- passed.
port 2 test status: 0x00000000 -- passed.
Test Complete: "spinfab" Pass 10 of 10
Duration 0 hr, 0 min & 41 sec (0:0:41:877).
passed.