HP StorageWorks Fabric OS 5.0.0 Command Reference Guide (AA-RW1MA-TE, May 2005)

660 Fabric OS commands
Port State Port state information
No_Card
No_Module
Mod_Val
No_Light
No_Sync
In_Sync
Laser_Flt
Port_Flt
Diag_Flt
Lock_Ref
Testing
Online
No interface card present.
No module (SFP or other) present.
Module validation in process.Mod_Inv – nvalid module.
Module not receiving light.
Module receiving light but out of sync.
Module receiving light and in sync.
Module signaling a laser fault.
Port marked faulty.
Port failed diagnostics.
Locking to the reference signal.
Running diagnostics.
Port is up and running.
comment The comment field is blank, or displays:
Disabled
Bypassed
Loopback
E_Port
F_Port
G_Port
L_Port
(Trunk master)
(upstream)
(downstream)
Port is disabled.
Port is bypassed (loop only).
Port is in loopback mode.
Fabric port; displays WWN and name of attached
switch.
Point-to-point port; displays WWN of attached N_Port.
Point-to-point but not yet E_Port or F_Port.
Loop port; displays number of NL_Ports.
Port is the master port in a group of trunking ports.
(Trunk port, master is port #x) – Port is configured as a
trunking port; the master port is port number x.
E_Port is an upstream path towards the principal switch
of the fabric.
E_Port is a downstream path away from the principal
switch of the fabric.
Persistently Disabled
This port has been disabled using