HP StorageWorks Fabric OS 5.0.0 Command Reference Guide (AA-RW1MA-TE, May 2005)

Fabric OS 5.0.0 command reference guide 677
Diagnostics
Each diagnostic test in this suit might report its own set of error messages when it detects failure(s). Refer to
the Diagnostics section of individual diagnostic test help pages. These messages are available only in the
log file.
Refer to the HP StorageWorks Fabric OS 4.x diagnostics and system error messages reference guide for
more information.
Examples
To initiate a system verification test on all switches in the fabric:
-unit id Use to focus testing on a single FRU in the system. The id for a
FRU type of BLADE correlates to the slot number of the FRU to be
tested.
switch:admin> systemverification -short
systemverification: Setting parameters for short run.
systemverification: burnin parameters.
CURRENT - KEYWORD : DEFAULT
1 - number_of_runs : 1
2 - vib : 2
10 - thermal : 10
SYSTEMVERIFICATION - label : BURNIN
2 - min_lb_mode : 2
1 - tbr_passes : 1
1 - prt_on : 1
1 - cntmem_on : 1
1 - cmi_on : 1
1 - retention_on : 1
1 - cam_on : 1
1 - flt_passes : 50
1 - sta_passes : 25
1 - plb_nframes : 100
1 - txd_nframes : 50
1 - xpt_nframes : 200
1 - bpt_nframes : 20
1 - slk_nmegs : 50
1 - bpt_all_nframes : 30
1 - slk_all_nmegs : 50
systemverification: Arming the burnin run on switch 0.
systemverification: Starting burnin on Switch 0
systemverification: Monitoring progress of the burnin activity.
systemverification: Outputting Status
State Status Run Cmd TotCmds Script
COMPLETED PASS 1 22 22 switchburnin.sh