HP StorageWorks Fabric OS 5.0.0 Diagnostics and System Error Messages Reference Guide (AA-RW1SA-TE, May 2005)

100 Messages
Recommended action
The fabric daemon takes proper action to recover from the error.
If the message persists, run supportFtp as needed to set up automatic FTP transfers and then run the
supportSave command and contact your switch service provider.
Severity
WARNING
FABR-1013
Message
Probable cause
The switch has insufficient memory for the fabric module to allocate. This message is rare and usually
indicates a problem with Fabric OS.
Recommended action
The system recovers by failing over to the standby CP.
If the message persists, run supportFtp as needed to set up automatic FTP transfers and then run the
supportSave command and contact your switch service provider.
Severity
CRITICAL
FABR-1014
Message
Probable cause
The specified port received an RDI (request domain ID) accept message containing a
principal-switch-assigned domain ID that is different from the insistent domain ID (IDID). If an RDI response
has a different domain ID, then the port is disabled.
Recommended action
1. Run the configShow command to view the fabric.ididmode.
A value of 0 means the IDID mode is disabled; a value of 1 means it is enabled.
2. Set the switch to insistent domain ID mode. This mode is set under the configure command or in
Web Tools on the Switch Admin > configure window.
timestamp, [FABR-1013], sequence-number,, CRITICAL, system-name, No
Memory: pid=fabric-process-ID file=source-file-name
line=line-number-within-the-source-file
timestamp, [FABR-1014], sequence-number,, ERROR, system-name, Port
port-number Disabled: Insistent Domain ID domain-ID could not be obtained.
Principal Assigned Domain ID = domain-ID