HP StorageWorks Fabric OS 5.0.0 Diagnostics and System Error Messages Reference Guide (AA-RW1SA-TE, May 2005)
Fabric OS 5.0.0 diagnostics and system error messages reference guide 167
FW-1242
Message
Probable cause
The number of EE CRC errors rose above the high boundary. Invalid CRC messages occur when the
number of CRC errors in Fibre Channel frames for specific source ID (S_ID) and destination ID (D_ID)
pairs change. These messages may also be caused by dirty equipment, temperature fluctuations, and
aging equipment.
Recommended action
The CRC error area of the End-to-End Performance Monitor class helps the user tune the fabric. To reduce
CRC errors, experiment with alternative topologies and cabling schemes. Clean equipment, check
temperatures, and replace old hardware.
Severity
WARNING
FW-1243
Message
Probable cause
The number of EE CRC errors changed from a value outside the acceptable range to a value within the
acceptable range. Invalid CRC messages occur when the number of CRC errors in Fibre Channel frames
for specific source ID (S_ID) and destination ID (D_ID) pairs change. These messages may also be caused
by dirty equipment, temperature fluctuations, and aging equipment.
Recommended action
No action is required. Respond to this message as is appropriate for the relevant policy of the end-user
installation.
Severity
INFO
timestamp, [FW-1242], sequence-number,, WARNING, system-name, label, is
above high boundary(High=high-value, Low=low-value). Current value is
value unit.
timestamp, [FW-1243], sequence-number,, INFO, system-name, label, is
between high and low boundaries(High=high-value, Low=low-value). Current
value is value unit.