HP StorageWorks Fabric OS 5.0.0 Diagnostics and System Error Messages Reference Guide (AA-RW1SA-TE, May 2005)
176 Messages
Probable cause
The number of HTTP violations rose above the high boundary. HTTP violations indicate that a browser
connection request was received from an unauthorized IP address. The HTTP_POLICY contains a list of
TCP/IP addresses that are authorized to establish browser connections to the switches in the fabric. The IP
addresses use the standard dot notation (for example, 255.255.255.255).
Recommended action
Run the errShow command to determine the IP address that sent the request. Responses to security-class
messages depend on user policies. Consult your security administrator for response strategies and
policies.
Severity
WARNING
FW-1303
Message
Probable cause
The number of HTTP violations changed from a value outside the acceptable range to a value within the
acceptable range. HTTP violations indicate that a browser connection request was received from an
unauthorized IP address. The HTTP_POLICY contains a list of TCP/IP addresses that are authorized to
establish browser connections to the switches in the fabric. The IP addresses use the standard dot notation
(for example, 255.255.255.255).
Recommended action
No action is required.
Severity
INFO
FW-1304
Message
Probable cause
The number of API violations changed. API violations indicate that an API connection request was
received from an unauthorized IP address. The SNMP_POLICY contains a list of TCP/IP addresses that
are authorized to establish API connections to switches in the fabric. The IP addresses use standard dot
notation (for example, 255.255.255.255).
timestamp, [FW-1303], sequence-number,, INFO, system-name, label, is
between high and low boundaries(High=high-value, Low=low-value). Current
value is value unit.
timestamp, [FW-1304], sequence-number,, INFO, system-name, label, value
has changed(High=high-value, Low=low-value). Current value is value unit.