HP StorageWorks Fabric OS 5.0.0 Diagnostics and System Error Messages Reference Guide (AA-RW1SA-TE, May 2005)

Fabric OS 5.0.0 diagnostics and system error messages reference guide 181
Recommended action
Run the errShow command to determine the IP address that sent the request. Responses to security-class
messages depend on user policies. Consult your security administrator for response strategies and
policies.
Severity
WARNING
FW-1315
Message
Probable cause
The number of WSNMP violations changed from a value outside the acceptable range to a value within
the acceptable range. WSNMP violations indicate that an SNMP get/set operation request was received
from an unauthorized IP address.
Recommended action
No action is required.
Severity
INFO
FW-1316
Message
Probable cause
The number of SES violations changed. SES violations indicate that a SCSI Enclosure Services (SES)
request was received from an unauthorized WWN. The SES_POLICY contains a list of WWNs of device
ports that are allowed to access the SES Server functionality.
Recommended action
Run the errShow command to determine the IP address that sent the request. Responses to security class
messages depend on user policies. Consult your security administrator for response strategies and
policies.
Severity
INFO
timestamp, [FW-1315], sequence-number,, INFO, system-name, label, is
between high and low boundaries(High=high-value, Low=low-value). Current
value is value unit.
timestamp, [FW-1316], sequence-number,, INFO, system-name, label, value
has changed(High=high-value, Low=low-value). Current value is value unit.