HP StorageWorks Fabric OS 5.0.0 Diagnostics and System Error Messages Reference Guide (AA-RW1SA-TE, May 2005)
214 Messages
Recommended action
Replace the missing power supply.
Severity
WARNING
FW-1429
Message
Probable cause
The switch status is not in a healthy state because the power supplies are not in the correct slots for
redundancy.
Recommended action
Rearrange the power supplies so that one is in an odd slot and other in an even slot to make them
redundant.
Severity
WARNING
FW-1430
Message
Probable cause
The switch status is not in a healthy state because the number of faulty temperature sensors is greater than
or equal to the policy set by the switchStatusPolicySet command. A temperature sensor is faulty
when the sensor value is not in the acceptable range or is faulty.
Recommended action
Replace the FRU with the faulty temperature sensor.
Severity
WARNING
timestamp, [FW-1429], sequence-number,, WARNING, system-name, Switch
status change contributing factor: Power supplies are not redundant.
timestamp, [FW-1430], sequence-number,, WARNING, system-name, Switch
status change contributing factor Temperature sensor: number-bad bad.