HP StorageWorks Fabric OS 5.0.0 Diagnostics and System Error Messages Reference Guide (AA-RW1SA-TE, May 2005)

224 Messages
Hardware independent layer error messages
HIL-1101
Message
Probable cause
The blade voltage is above threshold. This message is specific to the Core Switch 2/64 or SAN Director
2/128.
Recommended action
Replace the faulty blade.
Severity
ERROR
HIL-1102
Message
Probable cause
The blade voltage is below threshold. This message is specific to the Core Switch 2/64 or SAN Director
2/128.
Recommended action
Replace the faulty blade.
Severity
ERROR
HIL-1103
Message
timestamp, [HIL-1101], sequence-number,, ERROR, system-name, Slot
slot-number faulted, nominal-voltage (measured-voltage) is above
threshold.
timestamp, [HIL-1102], sequence-number,, ERROR, system-name, Slot
slot-number faulted, nominal-voltage (measured-voltage) is below
threshold.
timestamp, [HIL-1103], sequence-number,, ERROR, system-name, Blower
blower-number faulted, nominal-voltage (measured-voltage) is above
threshold.