HP StorageWorks Fabric OS 5.0.0 Diagnostics and System Error Messages Reference Guide (AA-RW1SA-TE, May 2005)

Fabric OS 5.0.0 diagnostics and system error messages reference guide 233
Severity
ERROR
HIL-1308
Message
Probable cause
All fans failed. This message is often preceded by a low-fan-speed message.
Recommended action
Replace the faulty fan FRUs immediately.
Severity
ERROR
HIL-1309
Message
Probable cause
Multiple fans failed. This message is often preceded by a low-fan-speed message.
Recommended action
Replace the faulty fan FRUs immediately.
Severity
ERROR
HIL-1401
Message
Probable cause
One fan FRU was removed.
timestamp, [HIL-1308], sequence-number,, ERROR, system-name, All
fans failed. Replace failed fan FRUs immediately.
timestamp, [HIL-1309], sequence-number,, ERROR, system-name, count fan
FRU(s) failed. Replace failed fan FRU(s) immediately.
timestamp, [HIL-1401], sequence-number,, WARNING, system-name, One fan FRU
missing. Install fan FRU immediately.