HP StorageWorks Fabric OS 5.0.0 Diagnostics and System Error Messages Reference Guide (AA-RW1SA-TE, May 2005)

Fabric OS 5.0.0 diagnostics and system error messages reference guide 235
Probable cause
One or more fan FRUs were removed.
Recommended action
Install the missing fan FRUs immediately.
Severity
WARNING
HIL-1501
Message
Probable cause
The temperature of this blade rose above the warning threshold.
Recommended action
1. Run the fanShow command to verify that all fans are operating properly.
2. Make sure that the area is well ventilated and that the room temperature is within the operational
range of your switch. Refer to the hardware reference manual for your switch for the operational
temperature range.
Severity
WARNING
HIL-1502
Message
Probable cause
The temperature of this blade rose above the critical threshold. This usually follows a high-temperature
message.
Recommended action
1. Run the fanShow command to verify all the fans are working properly.
2. Make sure that the area is well ventilated and that the room temperature is within the operational
range of your switch. Refer to the hardware reference manual for your switch for the operational
temperature range.
3. If the message persists, replace the blade.
timestamp, [HIL-1501], sequence-number,, WARNING, system-name,
Slot slot-number, high temperature (measured-temperature).
timestamp, [HIL-1502], sequence-number,, CRITICAL, system-name, Slot
slot-number, high temperature (measured-temperature). Unit will be shut