HP StorageWorks Fabric OS 5.0.0 Diagnostics and System Error Messages Reference Guide (AA-RW1SA-TE, May 2005)

236 Messages
Severity
CRITICAL
HIL-1503
Message
Probable cause
The temperature of this blade kept above the maximum threshold for at least two minutes. The blade is
shut down to prevent further damage. This usually follows a high-temperature warning message.
Recommended action
1. Run the fanShow command to verify all the fans are working properly.
2. Make sure that the area is well ventilated and that the room temperature is within operational range
of your switch. Refer to the hardware reference manual for your switch for the operational
temperature range.
3. If the message persists, replace the faulty blade.
Severity
CRITICAL
HIL-1504
Message
Probable cause
Temperature in the system has returned to normal.
Recommended action
No action is required.
Severity
INFO
timestamp, [HIL-1503], sequence-number,, CRITICAL, system-name, Slot
slot-number, unit shutting down.
timestamp, [HIL-1504], sequence-number,, INFO, system-name, System within
normal temperature specifications (measured-temperature C).