HP StorageWorks Fabric OS 5.0.0 Diagnostics and System Error Messages Reference Guide (AA-RW1SA-TE, May 2005)

Fabric OS 5.0.0 diagnostics and system error messages reference guide 237
HIL-1505
Message
Probable cause
Temperature in the system rose above the warning threshold.
Recommended action
1. Run the fanShow command to verify all the fans are working properly.
2. Make sure that the area is well ventilated and that the room temperature is within operational range
of your switch. Refer to the hardware reference manual for your switch for the operational
temperature range.
Severity
WARNING
HIL-1506
Message
Probable cause
Temperature in the system rose above the critical threshold.
Recommended action
1. Run the fanShow command to verify that all fans are working properly. Replace any deteriorating
fan FRUs.
2. Make sure that the area is well ventilated and that the room temperature is within operational range
of your switch. Refer to the hardware reference manual for your switch for the operational
temperature range.
Severity
CRITICAL
timestamp, [HIL-1505], sequence-number,, WARNING, system-name,
High temperature (measured-temperature C) exceeds environmental
specifications.
timestamp, [HIL-1506], sequence-number,, CRITICAL, system-name, High
temperature (measured-temperature C) exceeds system temperature limit.
System will shut down within 2 minutes.