HP StorageWorks Fabric OS 5.0.0 Diagnostics and System Error Messages Reference Guide (AA-RW1SA-TE, May 2005)
282 Messages
SEC-1005
Message
Probable cause
The primary FCS received a data request from the specified domain.
For example, if the switch fails to update the database or is attacked (data injection), a message is
generated to the primary FCS to try to correct and resync with the rest of the switches in the fabric.
Recommended action
Check the fabric status, using secFabricShow to verify that the fabric is not being attacked by
unauthorized users.
Severity
INFO
SEC-1006
Message
Probable cause
Invalid data was received for any statistic-related command for security (secStatsShow or
secStatsReset).
The counter is updated automatically when a security violation occurs. This message may also occur if the
updating counter fails.
Recommended action
1. If the message is the result of a user command, retry the statistic command.
2. If the message persists, run supportFtp as needed to set up automatic FTP transfers.
3. Run the supportSave command and contact your switch service provider.
Severity
WARNING
timestamp, [SEC-1005], sequence-number,, INFO, system-name, Primary FCS
receives data request from domain domain-number
timestamp, [SEC-1006], sequence-number,, WARNING, system-name, Security
statistics error: Failed to reset due to invalid data.