HP StorageWorks Fabric OS 5.0.0 Diagnostics and System Error Messages Reference Guide (AA-RW1SA-TE, May 2005)

Fabric OS 5.0.0 diagnostics and system error messages reference guide 301
SEC-1073
Message
Probable cause
The specific policy type is empty. The security database is corrupted for unknown reasons.
Recommended action
Run supportFtp as needed to set up automatic FTP transfers and then run the supportSave command
and contact your switch service provider.
Severity
ERROR
SEC-1074
Message
Probable cause
A security command was run on a switch that is not allowed to run it either because it is in non-secure
mode or because it does not have required FCS privilege.
Recommended action
If a security operation that is not allowed in non-secure mode is attempted, do not perform the operation
in non-secure mode. In secure mode, run the command from a switch that has required privilege; that is,
either a backup FCS or primary FCS.
Severity
ERROR
SEC-1075
Message
Probable cause
A corruption during the distribution of the security database.
timestamp, [SEC-1073], sequence-number,, ERROR, system-name, No FCS policy
in list!
timestamp, [SEC-1074], sequence-number,, ERROR, system-name, Cannot
execute the command on this switch. Please check the secure mode and FCS
status.
timestamp, [SEC-1075], sequence-number,, ERROR, system-name, Fail to
operation new policy set on all switches.