HP StorageWorks Fabric OS 5.0.0 Diagnostics and System Error Messages Reference Guide (AA-RW1SA-TE, May 2005)

302 Messages
This can occur only when the primary FCS is distributing the security database to the other switches in the
fabric and local validation finds that an error occurred in the security database. This is a rare occurrence.
Recommended action
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be
in the ready state. If a switch is in the error state, the database may not be correctly updated for that
specific switch.
Severity
ERROR
SEC-1076
Message
Probable cause
The NoNodeWWNZoning option was changed. If the option is turned on, a zone member can be
added using node WWNs, but the member cannot communicate with others nodes in the zone.
Recommended action
Reenable the current zone configuration for the change to take effect.
Severity
ERROR
SEC-1077
Message
Probable cause
The policy could not be activated. Reasons can be no memory, switch busy, and so on.
Recommended action
Run the secFabricShow command to verify that all switches in the fabric are in the ready state. Retry
the command when all switches are ready.
Severity
ERROR
timestamp, [SEC-1076], sequence-number,, ERROR, system-name,
NoNodeWWNZoning option has been changed.
timestamp, [SEC-1077], sequence-number,, ERROR, system-name, Failed to
activate new policy set on all switches.