HP StorageWorks Fabric OS 5.0.0 Diagnostics and System Error Messages Reference Guide (AA-RW1SA-TE, May 2005)

Fabric OS 5.0.0 diagnostics and system error messages reference guide 303
SEC-1078
Message
Probable cause
A corruption occurred during the distribution of the security database.
This can occur only when the primary FCS is distributing the security database to the other switches in the
fabric and local validation finds that an error occurred in the security database. This is a rare occurrence.
Recommended action
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be
in the ready state. If a switch is in the error state, the database may not be correctly updated for that
specific switch.
Severity
ERROR
SEC-1079
Message
Probable cause
A corruption during the distribution of the security database.
This can occur only when the primary FCS is distributing the security database to the other switches in the
fabric and local validation finds that an error occurred in the security database. This is a rare occurrence.
Recommended action
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be
in the ready state. If a switch is in the error state, the database may not be correctly updated for that
specific switch.
Severity
ERROR
SEC-1080
Message
timestamp, [SEC-1078], sequence-number,, ERROR, system-name, No new data
to abort.
timestamp, [SEC-1079], sequence-number,, ERROR, system-name, Invalid
policy name policy-name.
timestamp, [SEC-1080], sequence-number,, ERROR, system-name, Operation
denied. Please, use secModeEnable command.