HP StorageWorks Fabric OS 5.0.0 Diagnostics and System Error Messages Reference Guide (AA-RW1SA-TE, May 2005)
Fabric OS 5.0.0 diagnostics and system error messages reference guide 331
SEC-1172
Message
Probable cause
The switch is unable to determine its role (primary FCS or backup FCS) in the secure fabric.
Recommended action
1. Verify that all switches in the fabric are in time synchronization with the primary and that no external
entity is trying to access the fabric.
2. When verification is complete, retry the operation.
Severity
ERROR
SEC-1173
Message
Probable cause
The switch lost contact with the primary FCS switch in the secure fabric. This could be caused by the
primary FCS being disabled.
Recommended action
If the primary FCS was disabled intentionally, no action is required; if not, check the primary FCS.
Severity
ERROR
SEC-1174
Message
Probable cause
The FCS or non-FCS password could not be set.
timestamp, [SEC-1172], sequence-number,, ERROR, system-name, Failed to
identify role.
timestamp, [SEC-1173], sequence-number,, ERROR, system-name, Lost contact
with Primary FCS switch.
timestamp, [SEC-1174], sequence-number,, ERROR, system-name, Failed to set
FCS-or-non-FCS password.