HP StorageWorks Fabric OS 5.0.0 Diagnostics and System Error Messages Reference Guide (AA-RW1SA-TE, May 2005)

368 Messages
Probable cause
The switch was enabled before it was ready.
Recommended action
1. If the message persists, run supportFtp as needed to set up automatic FTP transfers.
2. Run the supportSave command and contact your switch service provider.
Severity
ERROR
SWCH-1002
Message
Probable cause
The device is not present in the authorized profile list.
Recommended action
1. Verify that the device is authorized to log in to the switch. If the device is authorized, run the
secPolicyDump command to verify whether the specified device WWN is listed.
2. If it is not listed, run the secPolicyAdd command to add this device to an existing policy.
Severity
INFO
SWCH-1003
Message
Probable cause
The slot state was detected as inconsistent during failover or recovery.
Recommended action
On a Core Switch 2/64 or SAN Director 2/128 switch, first run the slotPowerOff command and then
run the slotPowerOn command.
On a SAN Switch 2/8V, SAN Switch 2/16V, SAN Switch 2/32, or SAN Switch 4/32 switch, reboot or
power cycle the switch.
timestamp, [SWCH-1002], sequence-number,, INFO, system-name, Security
violation: Unauthorized device wwn-name-of-device tries to flogin to port
port-number
timestamp, [SWCH-1003], sequence-number,, ERROR, system-name, Slot ENABLED
but Not Ready during recovery, disabling slot = slot-number(return-value)