HP StorageWorks Fabric OS 5.0.0 Diagnostics and System Error Messages Reference Guide (AA-RW1SA-TE, May 2005)
370 Messages
System controller error messages
SYSC-1001
Message
Probable cause
During the boot sequence one of the programs would not run on the system.
Recommended action
1. If the message is reported during a reboot after new firmware has been loaded, try reloading the
firmware using the firmwareDownload command.
2. If the message persists, a conflict may exist between the two versions of firmware or the nonvolatile
storage may be corrupted.
3. Run the supportFtp command as needed to set up automatic FTP transfers.
4. Run the supportSave command and contact your switch service provider.
Severity
CRITICAL
SYSC-1002
Message
Probable cause
The system timed out during a reboot or failover sequence, waiting for one or more programs to register
with system services or to fail over to active status.
Recommended action
The switch is in an inconsistent state, which can be corrected only by a reboot or power cycle. Before
rebooting the chassis, record the firmware version on the switch (or CP) and run the haDump command.
If this is a dual-CP switch, then gather the output from the CP in which this log message appeared.
Severity
CRITICAL
timestamp, [SYSC-1001], sequence-number,, CRITICAL, system-name, Failed to
runname-of-program-that-could-not-be-run-(string):system-internal-error-m
essage-(string)
timestamp, [SYSC-1002], sequence-number,, CRITICAL, system-name, Switch
bring-up timed out