HP StorageWorks Fabric OS 5.0.0 Diagnostics and System Error Messages Reference Guide (AA-RW1SA-TE, May 2005)

Fabric OS 5.0.0 diagnostics and system error messages reference guide 371
General system error messages
SYSM-1001
Message
Probable cause
The switch ran out of system memory.
Recommended action
1. Run the memShow command to view the switch memory usage.
2. Reboot or power cycle the switch.
Severity
CRITICAL
SYSM-1002
Message
Probable cause
A user executed either the switchShutdown or switchReboot command. All services were brought
down for a logical switch.
Recommended action
No action is required if the switchShutdown or switchReboot command was executed
intentionally. If the switchShutdown command was run, you must run the switchStart command to
restart traffic on the logical switch.
Severity
INFO
SYSM-1003
Message
timestamp, [SYSM-1001], sequence-number,, CRITICAL, system-name, No memory
timestamp, [SYSM-1002], sequence-number,, INFO, system-name, number,
Switch: switch-number
timestamp, [SYSM-1003], sequence-number,, INFO, system-name, number,
Switch: start-reason