HP StorageWorks Fabric OS 5.0.0 Diagnostics and System Error Messages Reference Guide (AA-RW1SA-TE, May 2005)

64 Messages
BL-1006
Message
Probable cause
The errors (mostly synchronization errors) on this blade are harmless. Probably, the standby CP blade
connected to the active CP blade has experienced transitory problems. This message occurs only on the
Core Switch 2/64 and SAN Director 2/128.
Recommended action
Check the standby CP. No action is required if the other blade is already removed or faulted.
Severity
INFO
BL-1007
Message
Probable cause
A failover occurred while a blade was initializing on the previously active CP. This message occurs only on
the Core Switch 2/64 and SAN Director 2/128.
Recommended action
No action is required. The blade is reinitialized. Because reinitializing a blade is a disruptive operation
and can stop I/O traffic, you may have to stop and restart the traffic during this process.
Severity
WARNING
timestamp, [BL-1006], sequence-number,, INFO, system-name, Blade
slot-number NOT faulted. Peer blade slot-number experienced abrupt
failure.
timestamp, [BL-1007], sequence-number,, WARNING, system-name, blade
#blade-number: blade state is inconsistent with EM. bl_cflags
0xblade-control-flags, slot_on slot-on-flag, slot_off slot-off-flag,
faulty faulty-flag, status blade-status