HP StorageWorks Fabric OS 5.0.0 Diagnostics and System Error Messages Reference Guide (AA-RW1SA-TE, May 2005)
70 Messages
BLOOM message that provides more information on the specific error. This message occurs only on the
Core Switch 2/64 and SAN Director 2/128.
The reason codes are as follows:
• 1 = Available buffer overflow
• 2 = Backend port buffer timeout
• 3 = Backend port got shut down
• 4 = Embedded port buffer timeout
• 5 = Excessive busy mini buffer
• 6 = Excessive RCC VC on E_Port
• 7 = Excessive RCC VC on FL_Port
• 8 = Fail detection buffer tag error
• 9 = Fail detection TX parity error
• 10 = EPI CMEM interrupt error
• 11 = CMI interrupt error
• 12 = Interrupt overrun
• 13 = FDET interrupt
• 14 = Interrupt suspended
• 15 = Filter LISTD error
• 16 = Unknown filter LIST error
• 17 = Wait for LPC open state
• 18 = Wait for Old port state
• 19 = Wait for Open init state
• 20 = TX parity error
• 21 = RAM parity error
• 22 = BISR or RAMINIT error
Recommended action
1. Make sure that the blade is seated correctly.
2. If the blade is seated correctly, reboot or power cycle the blade.
3. Run the systemVerification command to verify that the blade does not have hardware problems.
Refer to the HP StorageWorks Fabric OS 4.x command reference guide for more information on this
command.
4. If the message persists, replace the blade.
Severity
CRITICAL