HP StorageWorks Fabric OS 5.0.0 Diagnostics and System Error Messages Reference Guide (AA-RW1SA-TE, May 2005)

76 Messages
EM-1008
Message
Probable cause
A FRU inserted in the specified slot is not compatible with the switch software. The blade is not used. This
message occurs only on the Core Switch 2/64 and SAN Director 2/128.
Recommended action
Replace the blade. Make sure the replacement is compatible with your switch type.
Severity
CRITICAL
EM-1009
Message
Probable cause
The environmental monitor (EM) received an unexpected power-down notification from the specified FRU.
This may indicate a hardware malfunction in the FRU. This message occurs only on the Core Switch 2/64
and SAN Director 2/128.
The FRU-Id value is composed of a FRU-type string and an optional number to identify the unit, slot, or
port. The FRU-Id value can be:
Switch for fixed port count switches.
Slot 1 through Slot 10 for the Core Switch 2/64 and SAN Director 2/128.
PS 1 through PS 4 (power supplies) for the Core Switch 2/64 and SAN Director 2/128.
Fan 1 through Fan 3 for the Core Switch 2/64, SAN Director 2/128.
WWN 1 or WWN 2 for the Core Switch 2/64 and SAN Director 2/128.
Recommended action
Try reseating the blade. If this fails to correct the error, replace the FRU unit.
Severity
CRITICAL
timestamp, [EM-1008], sequence-number,, CRITICAL, system-name,
Incompatible unit in FRU-Id is being faulted
timestamp, [EM-1009], sequence-number,, CRITICAL, system-name, FRU-Id
powered down unexpectedly