HP StorageWorks Fabric OS 5.0.0 Diagnostics and System Error Messages Reference Guide (AA-RW1SA-TE, May 2005)
Fabric OS 5.0.0 diagnostics and system error messages reference guide 77
EM-1010
Message
Probable cause
The environmental monitor received an unexpected power-down notification from the specified FRU.
However, the specified FRU still appears to be powered up after four seconds. This message occurs only
on the Core Switch 2/64 and SAN Director 2/128.
Recommended action
Try reseating the blade. If this fails to correct the error, replace the FRU unit.
Severity
CRITICAL
EM-1011
Message
Probable cause
The environmental monitor (EM) received an unexpected power-down notification from the FRU specified;
however, after four seconds the monitor cannot determine whether the FRU has powered down. This
message occurs only on the Core Switch 2/64 and SAN Director 2/128.
Recommended action
Try reseating the blade. If this fails to correct the error, replace the unit.
Severity
CRITICAL
EM-1012
Message
Probable cause
A switch blade failed to transition from one state to another. It is faulted. The specific failed target state
is displayed in the message. Serious internal Fabric OS configuration or hardware problems exist on the
switch.
timestamp, [EM-1010], sequence-number,, CRITICAL, system-name, Received
unexpected power down for FRU-Id But FRU-Id still has power
timestamp, [EM-1011], sequence-number,, CRITICAL, system-name, Can not
determine if FRU-Id has powered down
timestamp, [EM-1012], sequence-number,, CRITICAL, system-name, FRU-Id
failed state transition