HP StorageWorks Fabric OS 5.0.0 Diagnostics and System Error Messages Reference Guide (AA-RW1SA-TE, May 2005)
78 Messages
The FRU-Id value is composed of a FRU-type string and an optional number to identify the unit, slot, or
port. The FRU-Id value can be:
• Switch for fixed port count switches.
• Slot 1 through Slot 10 for the Core Switch 2/64 and SAN Director 2/128.
Recommended action
1. On Core Switch 2/64 and SAN Director 2/128, try reseating the indicated FRU.
2. If the message persists, reboot or power cycle the switch.
3. Run the systemVerification command to verify that the switch does not have hardware problems.
Refer to the HP StorageWorks Fabric OS 4.x command reference guide for more information on this
command.
4. If the message persists, replace the FRU.
Severity
CRITICAL
EM-1013
Message
Probable cause
The environmental monitor was unable to update the time alive or OEM data in the memory on a FRU.
The FRU-Id value is composed of a FRU-type string and an optional number to identify the unit, slot, or
port. The FRU-Id value can be:
• Switch for fixed port count switches.
• Slot 1 through Slot 10 for the Core Switch 2/64 and SAN Director 2/128.
• PS 1 through PS 4 (power supplies) for the Core Switch 2/64 and SAN Director 2/128, or PS 1
through PS 2 for the SAN Switch 2/32 and SAN Switch 4/32. The power supplies on the SAN Switch
2/8V and the SAN Switch 2/16V are not field replaceable.
• Fan 1 through Fan 3 for the Core Switch 2/64, SAN Director 2/128, and SAN Switch 4/32 (six
fans in three FRUs). Fan 1 through Fan 6 for the SAN Switch 2/32 (six fans in three FRUs). The fans
on the SAN Switch 2/8V and the SAN Switch 2/16V are not field replaceable.
• WWN 1 or WWN 2 for the Core Switch 2/64 and SAN Director 2/128. Only bladed switches have
removable WWN cards. All other switches have a non-removable WWN component on the main
logic board.
The SAN Switch 2/8V has one power supply and three fans, and the SAN Switch 2/16V has two power
supplies and four fans. Values for the individual fans and power supplies for these switches may appear,
but these parts cannot be replaced. The switch itself is a FRU.
Recommended action
If the fruInfoSet command was being run, try the command again; otherwise, the update is
automatically reattempted. If it continues to fail, try reseating the FRU.
timestamp, [EM-1013], sequence-number,, ERROR, system-name, Failed to
update FRU information for FRU-Id