HP StorageWorks Fabric OS 5.0.0 Diagnostics and System Error Messages Reference Guide (AA-RW1SA-TE, May 2005)
Fabric OS 5.0.0 diagnostics and system error messages reference guide 83
Probable cause
The environmental monitor (EM) found a switch blade that is inserted, but at least one ejector switch is not
latched. The blade in the specified slot is treated as not inserted. This message occurs only on the Core
Switch 2/64 and SAN Director 2/128.
Recommended action
Close the ejector switch if the FRU is intended for use.
Severity
ERROR
EM-1033
Message
Probable cause
The standby CP has been detected as faulty. The High Availability feature is not available. This message
occurs every time the other CP reboots, even as part of a clean warm failover. In most situations, this
message is followed by the EM-1047 message, and no action is required for the CP; however, you may
want to find out why the failover occurred. This message occurs only on the Core Switch 2/64 and SAN
Director 2/128.
Recommended action
1. If the standby CP was just rebooted, wait for the error to clear; run slotShow to determine whether it
has cleared. Watch for the EM-1047 message to verify this error cleared.
2. If the standby CP continues to be faulty or if it was not intentionally rebooted, check the error logs on
the other CP (using the errDump command) to determine the cause of the error state.
3. If the state persists, try reseating the FRU.
4. If the message persists, replace the FRU.
Severity
ERROR
EM-1034
Message
Probable cause
The specified FRU has been marked as faulty for the specified reason.
timestamp, [EM-1033], sequence-number,, ERROR, system-name, CP in FRU-Id
set to faulty because CP ERROR asserted
timestamp, [EM-1034], sequence-number,, ERROR, system-name, FRU-Id set to
faulty, rc=return-code