HP StorageWorks Fabric OS 5.0.0 Diagnostics and System Error Messages Reference Guide (AA-RW1SA-TE, May 2005)
Fabric OS 5.0.0 diagnostics and system error messages reference guide 87
Recommended action
The specified FRU is not responding to commands and should be replaced.
Severity
WARNING
EM-1044
Message
Probable cause
The specified FRU cannot be powered on because the associated logical switch is shut down.
Recommended action
Run the switchStart command on the associated logical switch.
Severity
WARNING
EM-1045
Message
Probable cause
An automatic power adjustment is being made because of the (predicted) failure of a power supply or the
insertion or removal of a port blade. If new_state is On, a port blade is being powered on because
more power is available (either a power supply was inserted or a port blade was removed or powered
down).
If new_state is Off, a port blade has been powered down because a power supply has been faulted,
because it is indicating a predicted failure.
If new_state is Down (not enough power), a newly inserted port blade was not powered on because
insufficient power is available.
Recommended action
The Core Switch 2/64 requires two power supplies for a fully populated chassis; however, you should
always operate the system with four operating power supplies for redundancy.
The SAN Director 2/128 requires only a single power supply for a fully populated chassis; however, you
should always operate the system with at least two power supplies for redundancy.
timestamp, [EM-1044], sequence-number,, WARNING, system-name, Can't power
on FRU-Id, its logical switch is shut down
timestamp, [EM-1045], sequence-number,, WARNING, system-name,
FRU-Id is being powered new-state