HP StorageWorks Fabric OS 5.0.0 Fabric Watch User Guide (AA-RW1TA-TE, May 2005)
Table Of Contents
- Contents
- About this guide
- An introduction to Fabric Watch
- Fabric Watch concepts
- Fabric watch components
- Configuring events
- Port persistence
- Notification methods
- Switch policies
- Interpreting event messages
- Activating and accessing Fabric Watch
- Configuring Fabric Watch
- Configuring Fabric Watch thresholds
- Configuring notifications
- Configuring switch status policy
- Configuring FRUs
- Configuring Fabric Watch using Web Tools
- Configuring Fabric Watch using SNMP
- Generating Fabric Watch reports
- Default threshold values
- Basic Fabric Watch configuration guidelines
- Using Fabric Watch with configuration files
- Glossary
- Index

55Fabric OS 5.0.0 Fabric Watch user guide
The system generates output similar to the following screen. The output you see varies based
on the class and area you select. In the Advanced Configuration menu shown here, the output
is based on the E-Port class and RXPerformance area.
1 : refresh
2 : disable a threshold
3 : enable a threshold
4 : advanced configuration
5 : return to previous page
Select choice => : (1..5) [5] 4
Index ThresholdName BehaviorType BehaviorInt
8 eportRXPerf008 Triggered 1
17 eportRXPerf017 Triggered 1
26 eportRXPerf026 Triggered 1
27 eportRXPerf027 Triggered 1
28 eportRXPerf028 Triggered 1
29 eportRXPerf029 Triggered 1
Threshold boundary level is set at : Default
Default Custom
Unit Percentage(%) Percentage(%)
Time base minute minute
Low 0 0
High 100 0
BufSize 0 0
Threshold alarm level is set at : Default
Errlog-1, SnmpTrap-2, PortLogLock-4
RapiTrap-8, EmailAlert-16
Valid alarm matrix is 31
Default Custom
Changed 0 0
Below 0 0
Above 0 0
InBetween 0 0
1 : change behavior type 11 : change threshold alarm level
2 : change behavior interval 12 : change changed alarm
3 : change threshold boundary level 13 : change below alarm
4 : change custom unit 14 : change above alarm
5 : change custom time base 15 : change inBetween alarm
6 : change custom low 16 : apply threshold alarm changes
7 : change custom high 17 : cancel threshold alarm changes
8 : change custom buffer 18 : return to previous page
9 : apply threshold boundary changes
10 : cancel threshold boundary changes
Select choice => : (1..18) [18]