Fabric Watch displays the units of measurement (Unit), time base (Time base), low threshold
(Low), high threshold (High) and buffer size (BufSize) for each column. See the following
screen.
In this example, a value of 80% is chosen as the custom high value for RXPerformance. The
default value is 10.
1 : change behavior type 11 : change threshold alarm level
2 : change behavior interval 12 : change changed alarm
3 : change threshold boundary level 13 : change below alarm
4 : change custom unit 14 : change above alarm
5 : change custom time base 15 : change inBetween alarm
6 : change custom low 16 : apply threshold alarm changes
7 : change custom high 17 : cancel threshold alarm changes
8 : change custom buffer 18 : return to previous page
9 : apply threshold boundary changes
10 : cancel threshold boundary changes
Select choice => : (1..18) [18] 7
Enter high threshold => : (0..100) [0] 80
Index ThresholdName BehaviorType BehaviorInt
8 eportRXPerf008 Triggered 1
17 eportRXPerf017 Triggered 1
26 eportRXPerf026 Triggered 1
27 eportRXPerf027 Triggered 1
28 eportRXPerf028 Triggered 1
29 eportRXPerf029 Triggered 1
Threshold boundary level is set at : Default
Default Custom
Unit Percentage(%) Percentage(%)
Time base minute minute
Low 0 0
High 100 80
BufSize 0 0
.
.
.