Configuring Fabric Watch64
Table 16 describes the 18 customization options displayed at the end of the Advanced
Configuration menu. With the exception of the last option, which exits advanced
configuration mode, each option has similar behavior. For each option, one or two lines will
appear, prompting you to accept the new setting information, and, after the information has
been provided, the entire screen will refresh to display the updated information.
Table 16 Advanced configuration options
Option Effect Input information
change behavior type Changes the behavior type of
a single element to either
Triggered or Continuous. The
change is volatile because
this option is not saved to
flash memory. Every time the
switch is rebooted, this option
is reset.
The element index and the
required behavior type
change behavior interval Changes the behavior interval
for a single element. The
change is volatile because
this option is not saved to
flash memory. Every time the
switch is rebooted, this option
is reset.
The element index and the
required behavior interval, in
seconds
change threshold
boundary level
Changes between the factory
default and custom threshold
information.
The required threshold column
change custom unit Changes the measurement
unit assigned to the monitored
data values, but only affects
the custom column.
The required measurement unit,
as a string
change custom time base Changes the time base for the
area, but only affects the
custom column.
The required time base
change custom low Changes the low setting for
the threshold, but only affects
the custom column.
The required low threshold, in the
units defined by the area
change custom high Changes the high setting for
the threshold, but only affects
the custom column.
The required high threshold, in
the units defined by the area