HP StorageWorks Fabric OS 5.0.0 MIB Reference Guide (AA-RW1QA-TE, May 2005)
Fabric OS 5.0.0 MIB reference guide 107
Fx_Port fabric login table
This table contains one entry for each Fx_Port in the fabric element and the Service Parameters that have
been established from the most recent fabric login, whether implicit or explicit.
fcFxlogiTable
OID 1.3.6.1.3.42.2.1.2.4
Description A table that contains, one entry for each Fx_Port in the fabric element, services
parameters established from the most recent fabric login, explicit or implicit.
fcFxlogiEntry
OID 1.3.6.1.3.42.2.1.2.4.1
Description An entry that contains service parameters established from a successful fabric login.
Index fcFxloginModuleIndex, fcFxloginFxPortIndex, fcFxloginNxPortIndex
fcFxlogiModuleIndex
OID 1.3.6.1.3.42.2.1.2.4.1.1
Description Identifies the module containing the Fx_Port for which this entry contains information.
fcFxlogiFxPortIndex
OID 1.3.6.1.3.42.2.1.2.4.1.2
Description Identifies the Fx_Port within the module. This number ranges from 1 to the value of
fcFeModuleFxPortCapacity for the associated module. The value remains constant for the
identified Fx_Port until the module is reinitialized.
fcFxlogiNxPortIndex
OID 1.3.6.1.3.42.2.1.2.4.1.3
Description Identifies the associated Nx_Port in the attachment for which the entry contains
information.
fcFxPortFcphVersionAgreed
OID 1.3.6.1.3.42.2.1.2.4.1.4
Description The version of FC-PH that the Fx_Port has agreed to support from the fabric login.
fcFxPortNxPortBbCredit
OID 1.3.6.1.3.42.2.1.2.4.1.5
Description The total number of buffers available for holding Class 1 connect-request Class 2 or Class
3 frames to be transmitted to the attached Nx_Port. It is for buffer-to-buffer flow control in
the direction from Fx_Port to Nx_Port. The buffer-to-buffer flow control mechanism is
indicated in the respective fcFxPortBbCreditModel.