HP StorageWorks Fabric OS 5.0.0 MIB Reference Guide (AA-RW1QA-TE, May 2005)

Fabric OS 5.0.0 MIB reference guide 157
swSensorType
OID 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.2
Description The type of sensor.
swSensorStatus
OID 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.3
Description The current status of the sensor. Possible values are:
• Unknown (1); the status of the sensor is unknown.
• Faulty (2); the status of the sensor is faulty.
• Below-min (3); the sensor value is below the minimal threshold.
• Nominal (4); the status of the sensor is nominal.
• Above-max (5); the sensor value is above the maximum threshold.
• Absent (6); the sensor is missing.
Note See the following list for valid values:
• For Temperature, valid values are 3 (below-min), 4 (above-max), and 4 (nominal).
• For Fan, valid values are 3 (below-min), 4 (nominal), and 6 (absent).
• For Power Supply, valid values are 2 (faulty), 4 (nominal), and 6 (absent).
swSensorValue
OID 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4
Description The current value (reading) of the sensor.
The value –2147483648 represents the maximum integer value; it also means that the
sensor does not have the capability to measure the actual value. In v2.0, the temperature
sensor value is in Celsius, the fan value is in revolutions per minute (RPM), and the power
supply sensor reading is unknown.
Note The unknown value –2147483648 indicates the maximum integer value.
swSensorInfo
OID 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.5
Description Additional information on the sensor; the sensor type and number, in text format. For
example, Temp 3 or Fan 6.