For an entry to be considered valid, both the X (local) and the Y (remote) values need to
have one valid value.
connUnitLinkEntry
OID 1.3.6.1.3.94.1.12.1
Description An entry describing a particular link to another.
Index connUnitLinkUnitId, connUnitLinkIndex
connUnitLinkUnitId
OID 1.3.6.1.3.94.1.12.1.1
Description The connUnitId of the connectivity unit that contains this link table.
Note Set to WWN of the local switch.
connUnitLinkIndex
OID 1.3.6.1.3.94.1.12.1.2
Description Creates a unique value for each entry in the link table with the same connUnitLinkUnitId.
The value can be reused only if it is not currently in use and the value is the next
candidate to be used. This value is allowed to wrap at the highest value represented by
the number of bits and is reset to 0 when the system is reset and the first value to be used
is 1.
Note Indexes 1 through maximum number of ports is reserved for ISL.
Indexes maximum number of ports + 1 and above are reserved for end devices and are
calculated based on portID of the end devices.
connUnitLinkNodeIdX
OID 1.3.6.1.3.94.1.12.1.3
Description The node WWN of the unit at one end of the link. If the node WWN is unknown and
the node is a connUnit in the responding agent, then the value of this object must be
equal to its connUnitId.
Note WWN of the local switch.
connUnitLinkPortNumberX
OID 1.3.6.1.3.94.1.12.1.4
Description The port number on the unit specified by connUnitLinkNodeIdX, if known; otherwise, -1.
If the value is nonnegative, it is equal to connUnitPortPhysicalNumber.
Note ISL: Physical port number of the E_Port.