HP StorageWorks Fabric OS 5.0.0 MIB Reference Guide (AA-RW1QA-TE, May 2005)

82 FE MIB objects
fcFxPortPhysRttov
OID 1.3.6.1.2.1.75.1.2.2.1.4
Description The Receiver_Transmitter_Timeout value of the Fx_Port. This is used by the receiver logic
to detect loss of synchronization.
Note This object is read-only. It is listed in the MIB definition as read-write, which is incorrect.
Fx_Port fabric login table
This table contains one entry for each Fx_Port in the fabric element and the service parameters that have
been established from the most recent fabric login, whether implicit or explicit.
fcFxloginTable
OID 1.3.6.1.2.1.75.1.2.3
Description A table that contains service parameters established from the most recent fabric login,
explicit or implicit, one entry for each Fx_Port in the fabric element.
fcFxloginEntry
OID 1.3.6.1.2.1.75.1.2.3.1
Description An entry containing service parameters established from a successful fabric login.
Index fcFxlogiModuleIndex, fcFxlogiNxPortIndex
fcFxPortNxLoginIndex
OID 1.3.6.1.2.1.75.1.2.3.1.1
Description The associated Nx_Port in the attachment for which the entry contains information.
fcFxPortFcphVersionAgreed
OID 1.3.6.1.2.1.75.1.2.3.1.2
Description The version of FC-PH that the Fx_Port has agreed to support from the fabric login.
fcFxPortNxPortBbCredit
OID 1.3.6.1.2.1.75.1.2.3.1.3
Description The total number of buffers available for holding Class 1 connect-request, and Class 2 or
Class 3 frames to be transmitted to the attached Nx_Port. It is for buffer-to-buffer flow
control in the direction from Fx_Port to Nx_Port. The buffer-to-buffer flow control
mechanism is indicated in the respective fcFxPortBbCreditModel.
fcFxPortNxPortRxDataFieldSize
OID 1.3.6.1.2.1.75.1.2.3.1.4
Description The Receive Data Field Size of the attached Nx_Port. This is a binary value that specifies
the largest Data Field Size for an FT_1 frame that can be received by the Nx_Port. The
value is a number of bytes in the range 128 to 2112, inclusive.