HP CM8060/CM8050 Color MFP with Edgeline Technology - System Administrator Guide

Menu item Sub-menu item Sub-menu item Values and Description
Reset Security Specify whether the current security settings on the
print server will be saved or reset to factory defaults.
No*: The current security settings are maintained.
Yes: Security settings are reset to factory defaults.
Diagnostics Embedded Tests This menu provides tests to help diagnose network
hardware or TCP/IP network connection problems.
Embedded tests help to identify whether a network fault
is internal or external to the device. Use an embedded
test to check hardware and communication paths on
the print server. After you select and enable a test and
set the execution time, you must select Execute to
initiate the test.
Depending on the execution time, a selected test runs
continuously until either the device is turned off, or an
error occurs and a diagnostic page is printed.
LAN HW Test CAUTION: Running this embedded test will erase
your TCP/IP configuration.
This test performs an internal loopback test. An internal
loopback test will send and receive packets only on the
internal network hardware. There are no external
transmissions on your network.
Select Yes to choose this test, or No to not choose it.
HTTP Test This test checks operation of HTTP by retrieving
predefined pages from the device, and tests the
embedded Web server.
Select Yes to choose this test, or No to not choose it.
SNMP Test This test checks operation of SNMP communications
by accessing predefined SNMP objects on the device.
Select Yes to choose this test, or No to not choose it.
Data Path Test This test helps to identify data path and corruption
problems on an HP postscript level 3 emulation device.
It sends a predefined PS file to the device, However,
the test is paperless; the file will not print.
Select Yes to choose this test, or No to not choose it.
Select All Tests Select this item to run all the embedded tests. Select
Yes to run all tests, or select No to not run all tests.
Execution Time [H] Use this item to specify the length of time (in hours) that
an embedded test will be run. You can select a value
from 1 to 60 hours. If you select zero (0), the test runs
indefinitely until an error occurs or device is turned off.
Data gathered from the HTTP, SNMP, and Data Path
tests is printed after the tests have completed.
Execute No*: Do not initiate the selected tests.
Yes: Initiate the selected tests.
Table 7-10 Embedded Jetdirect and EIO <X> Jetdirect menus (continued)
ENWW Initial Setup menu 137