HP PCL/PJL reference (PCL 5 Printer Language) - Technical Reference Manual Part I
EN Entity Status Responses 16-11
Entity Status Responses 
The status response for an Inquire Status Readback Entity command 
varies depending on the type of entity requested. The status 
responses for font, font extended, macro, user-defined pattern, 
and symbol set are described below.
Font Response 
The status response information returned for font (inquire entity value 
field 0) varies. Depending on whether the printer’s font is a bitmap, 
unbound scalable, or bound scalable, different keywords are returned. 
The response is also somewhat different if the location type is set to 1 
(currently selected, as explained in more detail later). The list of 
possible keywords for a font request is shown below.
SELECT= 
SYMBOLSETS= 
LOCTYPE= 
LOCUNIT=
An example of an inquire entity font (entity type 0) status response is 
shown below. Notice the variation in the keyword lines for the three 
fonts, listed in order below:
Internal, bitmap, Line Printer
Internal, unbound scalable, CG Times italic 
Downloaded, bound scalable, (CG Palacio)
Font status:
PCL 
INFO FONTS 
SELECT=“<Esc>(8U<Esc>(s0p16.67h8.5v0s0b0T”
SELECT=“<Esc>(s1p__v1s0b4101T” 
SYMBOLSETS=“0D,0I,0N,0S,0U,1E,1F,1G,...” 
SELECT=“<Esc>(1U<Esc>(s1p__v0s0b4111T<Esc>(21X”
 M
In a font status response, individual fonts are identified by the 
“SELECT=” keyword line, as shown in the example above. This 
line identifies the font by specifying the font selection characteristics 
(symbol set, spacing, pitch, height, style, stroke weight, and 
typeface). The characteristics are listed as they would be sent to 
the printer to select the font (in priority order, highest priority to 
lowest). “SELECT=” is returned for all font types.