User's Manual
Advanced use
45
Calibrate the scanner
The bar code scanning device in the All-in-One is a model 5180 imager that was manufactured by
Hand Held Products. To understand the imager better or to modify settings, refer to the 5X80
Engine Series 5X10/5X80 User's Guide that can be downloaded at www.handheld.com
.
The 5X10/5X80 User's Guide contains configuration bar codes that can be used to customize the
desired allowable bar codes and to change options and settings on the imager.
Reset the standard product defaults
If you are not sure what programming options are in your imager, or if you have changed some
options and want the factory settings restored, scan the Standard Product Default Settings bar
code, below.
Figure 10-1 Standard product default settings bar code
NOTE: The light bar will briefly go out to indicate that the scan was completed successfully.
Upgrade firmware
1. Connect the All-in-One to a computer with a USB cable.
2. Open the HP sp400 Series Configuration Software. See "Download and install software."
3. Select the Update tab.
There are four types of firmware update files:
○ Firmware: the main program running on the All-in-One
○ FPGA: the processor configuration
○ Imager: the program running on the bar code scanner module
○ Communication: the program running on the wireless communication module
4. In the File boxes, enter the names of the update files. You can use the Browse button to
navigate to the update files.
NOTE: All of the update file names must have an “.hhp” extension.
5. Click the Write to Device button and wait for the completion messages to appear.
NOTE: The device may reboot in the process of upgrading.