Understanding Flex Links and the MAC Address-Table Move Update
Figure 15-2 VLAN Flex Links Load Balancing Configuration Example
MAC Address-Table Move Update
The MAC address-table move update feature allows the switch to provide rapid bidirectional
convergence when a primary (forwarding) link goes down and the standby link begins forwarding
traffic.
In Figure 15-3, switch A is an access switch, and ports 1 and 2 on switch A are connected to uplink
switches B and D through a Flex Link pair. Port 1 is forwarding traffic, and port 2 is in the backup state.
Traffic from the PC to the server is forwarded from port 1 to port 3. The MAC address of the PC has
been learned on port 3 of switch C. Traffic from the server to the PC is forwarded from port 3 to port 1.
If the MAC address-table move update feature is not configured and port 1 goes down, port 2 starts
forwarding traffic. However, for a short time, switch C keeps forwarding traffic from the server to the
PC through port 3, and the PC does not get the traffic because port 1 is down. If switch C removes the
MAC address of the PC on port 3 and relearns it on port 4, traffic can then be forwarded from the server
to the PC through port 2.
If the MAC address-table move update feature is configured and enabled on the switches in Figure 15-3
and port 1 goes down, port 2 starts forwarding traffic from the PC to the server. The switch sends a MAC
address-table move update packet from port 2. Switch C gets this packet on port 4 and immediately
learns the MAC address of the PC on port 4, which reduces the reconvergence time.
You can configure the access switch, switch A, to send MAC address-table move update messages. You
can also configure the uplink switches B, C, and D to get and process the MAC address-table move
update messages. When switch C gets a MAC address-table move update message from switch A,
switch C learns the MAC address of the PC on port 4. Switch C updates the MAC address table,
including the forwarding table entry for the PC. The switch then starts forwarding traffic from the server
to the PC through port 4, which reduces the loss of traffic from the server to the PC.