Cisco Gigabit Ethernet Switch Module for HP p-Class BladeSystem System Message Guide
2-2
Cisco Gigabit Ethernet Switch Module for the HP p-Class BladeSystem System Message Guide
380260-004
Chapter 2 Message and Recovery Procedures
ACLMGR Messages
• PLATFORM Messages, page 2-32
• PLATFORM_PM Messages, page 2-33
• PLATFORM_VLAN Messages, page 2-34
• PM Messages, page 2-35
• PORT_SECURITY Messages, page 2-43
• QOSMGR Messages, page 2-44
• RMON Messages, page 2-49
• SPAN Messages, page 2-49
• SPANTREE Messages, page 2-50
• SPANTREE_FAST Messages, page 2-58
• SPANTREE_VLAN_SW Messages, page 2-58
• STORM_CONTROL Messages, page 2-58
• SUPERVISOR Messages, page 2-59
• SUPQ Messages, page 2-59
• SW_MACAUTH Messages, page 2-61
• SW_VLAN Messages, page 2-62
• TCAMMGR Messages, page 2-68
• UDLD Messages, page 2-69
• UFAST_MCAST_SW Messages, page 2-71
• VQPCLIENT Messages, page 2-72
• WCCP Messages, page 2-73
ACLMGR Messages
This section contains the access-control list (ACL) manager messages. Most messages in this section are
the result of a switch memory shortage, which includes hardware memory and label space but not CPU
memory. Both kinds of memory shortages are described.
Error Message ACLMGR-2-NOMAP: Cannot create ACL Manager data structures for VLAN Map
[chars].
Explanation This message means that the ACL manager could not allocate the data structures needed
to describe a VLAN map into a form that can be loaded into hardware. This error is most likely
caused by lack of free memory. [chars] is the VLAN map name.
Recommended Action Reduce other system activity to ease memory demands.