Cisco Gigabit Ethernet Switch Module for HP p-Class BladeSystem System Message Guide

2-41
Cisco Gigabit Ethernet Switch Module for the HP p-Class BladeSystem System Message Guide
380260-004
Chapter 2 Message and Recovery Procedures
PM Messages
ignored for purposes of this count. If eight interfaces on the same module are in one bundle, and the
port channel is carrying VLAN 1, it counts as eight VLAN ports. [chars] is the module name (for
example, switch or the module number), and [dec] is the recommended limit.
Recommended Action Reduce the number of trunks and VLANs configured in the module or switch
as recommended in [dec]. Enter the show interfaces trunk privileged EXEC command to see the
total number of trunks and VLANs.
Error Message PM-4-NO_SUBBLOCK: No PM subblock found for [chars].
Explanation This message means that the port manager did not find the subblock for this interface.
[chars] is the interface name.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, contact HP technical support and
provide the representative with the gathered information. For more information about the online
tools and about contacting HP, see the
“Error Message Traceback Reports” section on page 1-5.
Error Message PM-4-PORT_BOUNCED: Port [chars] was bounced by [chars].
Explanation This message means that during a change-over when the port was in the link-down state,
the port manager restarted the port. A port can be restarted only when the port data structures are
not consistent in the active and standby supervisors. Active ports in the link-down state return to the
link-up state when the port is restarted. The first [chars] is the port number, and the second [chars]
is the re-activation event.
Recommended Action No action is required.
Error Message PM-4-PVLAN_TYPE_CFG_ERR: Failed to set VLAN [dec] to a [chars] VLAN.
Explanation This message means that the platform did not set a private VLAN type. [dec] is the
VLAN ID.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or
contact your Cisco technical support representative, and provide the representative with the gathered
information. For more information about these online tools and about contacting Cisco, see the
“Error
Message Traceback Reports” section on page 1-5.