Cisco Gigabit Ethernet Switch Module for HP p-Class BladeSystem System Message Guide

2-66
Cisco Gigabit Ethernet Switch Module for the HP p-Class BladeSystem System Message Guide
380260-004
Chapter 2 Message and Recovery Procedures
SW_VLAN Messages
Error Message SW_VLAN-4-VTP_INTERNAL_ERROR: VLAN manager received an internal error
[dec] from vtp function [chars] [chars].
Explanation This message means that the VLAN manager received an unexpected error code from
the VTP configuration software. [dec] is the error code, the first [chars] is the VTP function, and the
second [chars] is the error-code description.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, contact HP technical support and
provide the representative with the gathered information. For more information about the online
tools and about contacting HP, see the
“Error Message Traceback Reports” section on page 1-5.
Error Message SW_VLAN-4-VTP_INVALID_DATABASE_DATA: VLAN manager received bad data of
type [chars] value [dec] from vtp database function [chars].
Explanation This message means that the VLAN manager received invalid data from a VTP
configuration database routine. The first [chars] is the data type, [dec] is the inappropriate value that
was received, and the second [chars] is the VTP database function.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, contact HP technical support and
provide the representative with the gathered information. For more information about the online
tools and about contacting HP, see the
“Error Message Traceback Reports” section on page 1-5.
Error Message SW_VLAN-4-VTP_INVALID_EVENT_DATA: VLAN manager received bad data of
type [chars] value [dec] while being called to handle a [chars] event.
Explanation This message means that the VLAN manager received invalid data from the VTP
configuration software. The first [chars] is the data type, [dec] is the value of that data, and the
second [chars] is the VTP event.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, contact HP technical support and
provide the representative with the gathered information. For more information about the online
tools and about contacting HP, see the
“Error Message Traceback Reports” section on page 1-5.
Error Message SW_VLAN-4-VTP_SEM_BUSY: VTP semaphore is unavailable for function
[chars]. Semaphore locked by [chars].
Explanation This message means that the VTP database is not available. You should access the VTP
database later. The first [chars] is the function name that you want to configure, and the second
[chars] is the function name that is using the VTP database.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, contact HP technical support and
provide the representative with the gathered information. For more information about the online
tools and about contacting HP, see the
“Error Message Traceback Reports” section on page 1-5.