CSCth59458
If a redundant power supply (RSP) switchover occurs during a bulk configuration synchronization,
some of the line configurations might disappear.
The workaround is to reapply the line configurations.
CSCtl12389
The show ip dhcp pool command displays a large number of leased addresses.
The workaround is to turn off ip dhcp remember and reload the switch.
CSCtq64716
The following warning messages might be displayed during the boot process even when a RADIUS
or a TACACS server have been defined:
%RADIUS-4-NOSERVNAME:
or
%AAAA-4-NOSERVER: Warning: Server TACACS2 is not defined
There is no workaround.
CSCtr37757
The secure copy feature (copy: source-filename scp: destination-filename command) does not work.
There is no workaround.
CSCtz99447
Local web authorization and HTTP services on the switch do not respond because of a web
authorization resource limitation in the system. The resource limitation is normally caused by
incorrectly terminated HTTP or TCP sessions.
These are possible workarounds and are not guaranteed to solve the problem:
Enter the ip admission max-login-attempts privileged EXEC command to increase the number
of maximum login attempts allowed per user.
If the web authorization module is intercepting HTTP sessions from web clients in an attempt
to authorize them, try using a different browser.
Eliminate background processes that use HTTP transport.
CSCua54224
Heavy traffic load conditions may cause the loop guard protection function to be automatically
activated and almost immediately deactivated. These conditions can be caused by entering the
shutdown and no shutdown interface configuration commands or by interface link flaps on more
than forty ports. These log messages appear:
%SPANTREE-2-LOOPGUARD_BLOCK: Loop guard blocking port GigabitEthernet1/0/1 on MST0.
%SPANTREE-2-LOOPGUARD_UNBLOCK: Loop guard unblocking port GigabitEthernet1/0/1 on
MST0.
There is no workaround.
CSCua87594
When a peer switch sends inferior Bridge Protocol Data Units (BPDUs) on the blocking port of the
Cisco switch (with the proposal bit ON), the Cisco switch waits for three such BPDUs before
responding with a better BPDU. This leads to a convergence time of more than 5 seconds. The
problem appears under these conditions: