Chapter 1 Product Overview
Services Modules
LEDs on the 18/4-Port Multiservice Module
Table 1-6 describes the LEDs for the Cisco MDS 9000 Family 18/4-port Multiservice module.
14/2-Port Multiprotocol Services Module
The 14/2-port Multiprotocol Services (MPS-14/2) module provides 14 1-Gbps/2-Gbps Fibre Channel
autosensing ports and two 1-Gigabit Ethernet ports for iSCSI and FCIP over Gigabit Ethernet. The
MPS-14/2 module supports the intelligent features available on other modules, including VSANs,
security, and traffic management.
The 14 1-Gbps/2-Gbps autosensing Fibre Channel ports (labeled 1 through 14) are best used for
applications requiring high bandwidth; for example, Inter-Switch Link (ISL) connections between
switches and high-performance host or storage controllers. Each Fibre Channel port supports a sustained
data rate of up to 2 Gbps in each direction.
The Cisco MDS 9216 Switch supports one MPS-14/2 module. The two Gigabit Ethernet ports (labeled 1
and 2) provide 1-Gbps throughput for IP services, including iSCSI and FCIP over Gigabit Ethernet. The
MPS-14/2 also supports hardware-based encryption and compression for these Gigabit Ethernet ports.
This hardware-based encryption handles the computationally intensive IPsec feature for IP services.
Table 1-6 LEDs for the Cisco MDS 9000 Family 18/4-Port Multiservice Modules
LED Status Description
Status Green All diagnostics pass. The module is operational (normal
initialization sequence).
Orange One of the following occurs or occurred:
The module is booting or running diagnostics (normal
initialization sequence).
The inlet air temperature of the system exceeded the
maximum system operating temperature limit (a minor
environmental warning). To ensure maximum product
life, you should immediately correct the environmental
temperature and restore the system to normal operation.
Red One of the following occurred:
The diagnostic test failed. The module is not operational
because a fault occurred during the initialization
sequence.
The inlet air temperature of the system exceeded the safe
operating temperature limits of the card (a major
environmental warning). The card shut down to prevent
permanent damage.
Link Solid
green
Link is up.
Solid
yellow
Link is disabled by software.
Flashing
yellow
A fault condition exists.
Off No link.