Cisco MDS 9000 Family Release Notes for Cisco MDS SAN-OS Release 3.2(2c) (OL14116-03, November 2007)

Send documentation comments to mdsfeedback-doc@cisco.com
33
Cisco MDS 9000 Family Release Notes for Cisco MDS SAN-OS Release 3.2(2c)
OL-14116-03
Caveats
CSCsk95464
Symptom: When a server HBA port is flapped multiple times, the storage-based migration job
moves to the Reset state.
Workaround: This issue is resolved.
CSCsk96105
Symptom: If you upgrade to Cisco SAN-OS Release 3.2(2c) from a lower version, or downgrade
from Cisco SAN-OS Release 3.2(2c) to a lower version on an MDS 9124 switch, MDS 9134 switch,
Cisco Fabric Switch for HP c-Class BladeSystem, or a Cisco Fabric Switch for IBM BladeCenter,
zoning may not work as configured for the F ports connected to NPIV-capable hosts.
Workaround: This issue is resolved.
CSCsl25170
Symptom: On a switch running SAN-OS Release 3.2(1), Release 3.2(1a) or Release 3.2(2a) with 2
or more MDS-18/4 modules present, when upgrading to SAN-OS Release 3.2(2c) or later, only the
first MDS-18/4 module will be upgraded. The other MDS-18/4 modules will not be upgraded. They
will continue to run the older release.
Workaround: This issue is resolved.
CSCsl34881
Symptom: During a login to an MDS 9222 switch or an MDS 9134 switch, Performance Manager
incorrectly displays the Remote Node ID (RNID) when FICON is enabled.
Workaround: This issue is resolved.
CSCsh70425
Symptom: The administrator can configure a data migration job to be in the offline mode in one
fabric and in the online mode in another fabric.
Workaround: This issue is resolved.
CSCsj32048
Symptom: T10K tape drives are not supported for FICON tape acceleration as remote tape drives
behind the virtual shared memory (VSM).
Workaround: This issue is resolved.
CSCsk18352
Symptom: If a supervisor switchover occurs while Fabric Manager is creating a DMM migration
job, the job creation process times out.
Workaround: This issue is resolved.
CSCsk26424
Symptom: Removing a fabric and then adding the same fabric in Fabric Manager causes a session
fabric ID mismatch. As a result, hosts do not appear in the Step 1 window of the Fabric Manager
DMM job creation wizard.
Workaround: This issue is resolved.
CSCsk64172
Symptom: CFS does not successfully merge records from the persistent storage service (PSS)
pertaining to the data portion of events. This results in a PSS leak and a memory leak where a large
number of records in PSS cause long read and write access times.
Workaround: This issue is resolved.